to7<TMP>
Overtemperature on the controller (Kernel), <TMP> is the temperature indic-
ator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
to8<TMP>
Power module overtemperature error, <TMP> is the temperature indicator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
to9<TMP>
PFC module overtemperature error, <TMP> is the temperature indicator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
toA<TMP>
Overtemperature on the PC board LSTMAG20 (PFC), <TMP> is the tem-
perature indicator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
tu0<TMP>
Undertemperature on the PC board LSTMAG20 (secondary circuit), <TMP>
is the temperature indicator
Operate power source within the permitted temperature range
Cause:
Remedy:
tu2<TMP>
Undertemperature in the power source secondary circuit
Operate power source within the permitted temperature range
Cause:
Remedy:
tu3<TMP>
Undertemperature on the PC board LSTMAG20 (motor controller), <TMP>
is the temperature indicator
Operate power source within the permitted temperature range
Cause:
Remedy:
tu6<TMP>
Undertemperature on the PC board LSTMAG20 (voltage doubler), <TMP>
is the temperature indicator
Operate power source within the permitted temperature range
Cause:
Remedy:
tu7<TMP>
Undertemperature on the controller (Kernel), <TMP> is the temperature
indicator
Operate power source within the permitted temperature range
Cause:
Remedy:
tu8<TMP>
Power module undertemperature error, <TMP> is the temperature indicator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
tu9<TMP>
PFC module undertemperature error, <TMP> is the temperature indicator
Allow power source to cool down, check that fan is running
Cause:
Remedy:
tuA<TMP>
Undertemperature error on the PC board LSTMAG20 (PFC), <TMP> is the
temperature indicator
Operate power source within the permitted temperature range
Cause:
Remedy:
19