(5)(6) (6) (6) (5)(3) (4)
3
Fit the transformer lead (3) to the cur-
rent socket using a 17 mm screw as
shown
Tightening torque = 20 Nm
4
Connect the two leads (4) to the LST-
MAG20 PC board
5
Fit the primary transformer leads to
the LSTMAG20 PC board using two
M4x8 mm TX25 screws (5)
Tightening torque = 1.5 Nm
6
Fit the secondary transformer leads to
the LSTMAG20 PC board using three
M5x12 mm TX20 screws (6)
Tightening torque = 3.0 Nm
7
Close housing as described in section
"Closing the housing"