Select the relevant menu items:
- FdA
- FEd
FdA menu item
- If Aut is selected, automatic calibration can be carried out in the "FEd" menu item
- If OFF is selected, manual calibration can be carried out in the "FEd" menu item
FEd menu item
Automatic calibration:
1
Open the clamping lever
2
Press the "Wire threading" button
- The display will show "run" while the calibration is in progress (duration approx.
25s)
- Once the calibration has been completed, the digital display will read "FEd"
Manual calibration:
3
Open the clamping lever
4
Press the "Wire threading" button or the torch trigger
- Display shows „1.St 3.0“ an
5
Press the "Wire threading" button or the torch trigger
- Display shows "AdJ".
6
Measure the speed at the drive roller and set to 3 m/min (42,3 U/min) using the right
adjusting dial
- Display shows "rdY". The values have been stored internally
7
Press the "Wire threading" button or the torch trigger
- Display shows "2.nd 15.0“
8
Press the "Wire threading" button or the torch trigger
- Display shows "AdJ".
9
Measure the speed at the drive roller and set to 15 m/min (211,7 U/min) using the
right adjusting dial
- Display shows "rdY". The values have been stored internally
10
Press the "Wire threading" button or the torch trigger
- Once the calibration has been completed, the digital display will read "FEd"