If the wire-feed unit is attached to a crane holder during welding, always use a suitable, 
insulated wirefeeder hoisting attachment (MIG/MAG and TIG devices).
If the device has a carrying strap or handle, this is intended solely for carrying by hand. The 
carrying strap is not to be used if transporting with a crane, counterbalanced lift truck or 
other mechanical hoist.
All lifting accessories (straps, handles, chains, etc.) used in connection with the device or 
its components must be tested regularly (e.g. for mechanical damage, corrosion or chang-
es caused by other environmental factors).
The testing interval and scope of testing must comply with applicable national standards 
and directives as a minimum.
Odourless and colourless shielding gas may escape unnoticed if an adapter is used for the 
shielding gas connection. Prior to assembly, seal the device-side thread of the adapter for 
the shielding gas connection using suitable Teflon tape.
Requirement for 
the shielding gas
Especially with ring lines, contaminated shielding gas can cause damage to equipment and 
reduce welding quality.
Meet the following requirements regarding shielding gas quality:
- Solid particle size < 40 µm
- Pressure condensation point < -20 °C
- Max. oil content < 25 mg/m³
Use filters if necessary. 
Danger from 
shielding gas cyl-
inders
Shielding gas cylinders contain gas under pressure and can explode if damaged. As the 
shielding gas cylinders are part of the welding equipment, they must be handled with the 
greatest of care.
Protect shielding gas cylinders containing compressed gas from excessive heat, mechan-
ical impact, slag, naked flames, sparks and arcs.
Mount the shielding gas cylinders vertically and secure according to instructions to prevent 
them falling over.
Keep the shielding gas cylinders well away from any welding or other electrical circuits.
Never hang a welding torch on a shielding gas cylinder.
Never touch a shielding gas cylinder with an electrode.
Risk of explosion - never attempt to weld a pressurised shielding gas cylinder.
Only use shielding gas cylinders suitable for the application in hand, along with the correct 
and appropriate accessories (regulator, hoses and fittings). Only use shielding gas cylin-
ders and accessories that are in good condition.
Turn your face to one side when opening the valve of a shielding gas cylinder.
Close the shielding gas cylinder valve if no welding is taking place.
If the shielding gas cylinder is not connected, leave the valve cap in place on the cylinder.
The manufacturer's instructions must be observed as well as applicable national and inter-
national regulations for shielding gas cylinders and accessories.
Danger from es-
caping shielding 
gas
Risk of suffocation from the uncontrolled escape of shielding gas