52
Care, maintenance and disposal
General Under normal operating conditions, the welding system requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure the weld-
ing system remains in a usable condition for many years.
Safety
WARNING!
An electric shock can be fatal.
Before opening the device
Turn the mains switch to the "O" position
Unplug the device from the mains
Ensure the device cannot be switched back on
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
WARNING!
Work that is carried out incorrectly can cause serious injury and damage.
The following activities must only be carried out by trained and qualified personnel.
All instructions in the section headed "Safety rules" must be observed.
At every start-up - Check mains plug, mains cable, welding torch, interconnecting hosepack and ground
earth connection for damage
- Check that the device has an all-round clearance of 0.5 m (1 ft. 8 in.) to ensure that
cooling air can flow in and out freely
NOTE!
The air inlets and outlets must never be covered, not even partially.
Every 6 months - Dismantle device side panels and clean inside of device with dry, reduced com-
pressed air
CAUTION!
Danger of damage to electronic components.
Do not bring the air nozzle too close to electronic components.
Disposal Dispose of in accordance with the applicable national and local regulations.