up via "Energy per user". By entering "Total", the list can be downloaded as a .csv file.
The following data is displayed in the file:
- Number: Sequential number of the session.
A session is the period of time between connecting and disconnecting the charging
cable.
- Session ID: Unique identification number.
- ID chip: Indicates the registered ID chip. No entry if loaded without ID Chip.
- Proportion from Eco Mode [%]: Proportion of the charged energy from Eco Mode as
a percentage [%].
- Proportion from Next Trip Mode [%]: Proportion of the charged energy from Next
Trip Mode as a percentage [%].
- Start: Start date and time from which the charging cable is connected.
- End: End date and time when the charging cable is disconnected.
- Duration: Period of time during which the Wattpilot is in use.
- Charging time: Indicates the period of time during which energy was being charged
into the electric vehicle.
- Max. power [kW]: Indicates the maximum power in kilowatts [kW] reached during
charging.
- Max. current [A]: Indicates the maximum current in amperes [A] reached during
charging.
- Energy [kWh]: Indicates the charged energy in kilowatt hours [kWh].
- Proportion from PV [kWh]: Proportion of the charged energy in kilowatt hours [kWh]
provided by PV surplus.
- Proportion from battery [kWh]: Proportion of the charged energy in kilowatt hours
[kWh] provided by a stationary battery.
- Meter reading [kWh]: Indicates the total charged energy in kilowatt hours [kWh].
42