3-5
Left Display Right Display Action
attained. Press (YES) arrow to continue to DISCARD NOW
function. Press (NO) arrow to return to normal operation and
advance to next step.
-------- or LOW
TEMP alternating with
the temperature.
-------- or LOW
TEMP alternating
with the temperature.
None required. Fryer starts heating back to setpoint.
READY READY
None required. Displayed once the temperature returns to setpoint.
3.3.4 OQS Filter with OQS (Set to Text)
Left Display Right Display Action
FILTER
Press and hold FILTER button until FILTER is displayed.
LEFT (Split vats only)
RIGHT (Split vats
only)
Press appropriate arrow to select side.
OQS
Press the button.
OQS FILTER
NOW?
YES / NO
Press (YES) arrow to continue. Press (NO) arrow to bypass
filtration and return to previous state.
SKIM VAT or OIL
TOO LOW.
CONFIRM or OIL
TOO LOW display
Skim the vat and press arrow under CONFIRM. If the oil level is
too low, the controller displays “OIL TO LOW”. Fill the vat and
press either arrow under CONFIRM.
START
FILTRATION
Press button with blinking LED.
DRAINING
None required. If the drain becomes clogged, use the Fryer’s Friend
to clear the blockage.
FLUSHING
None required.
FILLING
None required.
TPM
X
/ X alternating
None required. The pump stops and the OQS sensor calculates the
TPM value of the oil.
FILLING
None required. The pump continues filling the frypot.
IS VAT FULL? YES / NO
Press (YES) if the vat is full.
If TPM reading is below OQS SETUP – DISCARD NOW and
DISCARD SOON limits, proceed to OIL IS GOOD step.
If TPM reading is below OQS SETUP – DISCARD NOW but
above DISCARD SOON limits, proceed to DISCARD SOON step.
If TPM reading is above OQS SETUP – DISCARD limits, proceed
to DISCARD NOW step.
If the TPM is out of range or an error occurs, proceed to final step
below.
OIL IS GOOD
None required. Return to normal operation and skip to ----------- or
LOW TEMP step below.
DISCARD SOON CONFIRM
Displayed if TPM reading is below OQS SETUP – DISCARD
NOW, but the TPM value has reached the DISCARD SOON limits,
press arrow under CONFIRM and skip to ----------- or LOW TEMP
step below.
DISCARD NOW? YES / NO
Displayed if the value in OQS SETUP – DISCARD NOW is
exceeded. Press (YES) arrow to continue to DISCARD NOW
function (see DISPOSE function in Chapter 2). Press (NO) arrow
to return to normal operation and advance to next step.
-------- or LOW
TEMP alternating with
the temperature.
-------- or LOW
TEMP alternating
with the temperature.
None required. Fryer starts heating back to setpoint.
READY READY
None required. Displayed once the temperature returns to setpoint.