3-1
CHAPTER 3: FILTERQUICK™ OIL QUALITY SENSOR (OQS)
3.1 OQS Filter Setup
With the controller OFF, follow the steps below. *NOTE: This should only be done on the far left (Master) controller.
Left Display Right Display Action
OFF OFF
Press until the controller scrolls INFO MODE, changing to MAIN and then
PRODUCT SETUP.
PRODUCT
SETUP
Press to scroll to Vat setup and press .
VAT SETUP
Enter
code
Enter 1656.
SYSTEM
Press to scroll to FILTER.
FILTER
Press .
Cooks
till
Filter
0
Press two times to scroll to OQS and press .
OQS DISABLED
Press to scroll to ENABLED and press . (Default is DISABLED.)
CLEAN
AND
FILTER
WITH OQS
CHOICE
Press  to scroll to CHOICE, YES or NO and press . (Default is CHOICE.)
CHOICE = Prompts for OQS during CLEAN AND FILTER. YES = Performs OQS
during CLEAN AND FILTER without a prompt. NO= OQS is disabled during
CLEAN AND FILTER.
OQS TYPE OC01v01
Press  to scroll through oil types OC01V01, OC02V01, etc. Use the table on
instruction sheet 8197316 to determine the oil type.
Ensure the oil type matches what the store is using. When complete press .
DISPLAY
TYPE
NUMBER
Press  to scroll to choice NUMBER or TEXT and press . (Default is
NUMBER.) NOTE: If set to NUMBER the Total Polar Materials is shown as a
number. If set to Text, only DISCARD SOON/CONFIRM, OIL IS GOOD or
DISCARD NOW is shown.
DISCARD
NOW
24
Use numbered keys to change the default setting of the TPM DISCARD NOW value
and press . (Default is 24. Minimum value is 15, maximum value is 30.)
DISCARD
SOON
4
Use numbered keys to change the default setting of the TPM DISCARD SOON value
and press . This is the offset value from DISCARD NOW which the DISCARD
SOON is displayed. Example: If the DISCARD NOW is set at 24, and the DISCARD
SOON is desired 4 TPM values below that, set the DISCARD SOON value to 4.
(Default is 4. Minimum value is 0=Disabled, maximum value is 15.) Set to “0” to
disable DISCARD SOON.
DISPOSE
DELAY
TIMER
30
Use numbered keys to change default setting for the DISCARD NOW delay timer
and press . This is the amount of time once the DISCARD NOW prompt is
displayed and bypassed before the DISCARD NOW message returns. (Default is: 30
minutes. Minimum value is :00 = DISABLED, maximum value is 4:00 hours.)
Exit Exit
Press the Exit/Scan button twice to return the controller to OFF.
3.2 INFO MODE: Viewing OQS Total Polar Material (TPM) Stats
The FilterQuick™ collects and stores information on the TPM values. This data is in the info mode, and is accessed by
pressing the checkmark key with the controller off or on. The steps to view the data are detailed below.
Left Display Right Display Action
OFF/ON OFF/ON
Press until INFO MODE is displayed and release.
LAST
DISPOSE
STATS
Press two times to scroll to TPM.