5-3
E codes: Extension Terminal Functions
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
E01 Terminal [X1] Function
㧙㧙
NY 05-40
E02 Terminal [X2] Function 0 (1000): Select multi-frequency (
SS1
)
㧙㧙
NY 1
E03 Terminal [X3] Function 1 (1001): Select multi-frequency (
SS2
)
㧙㧙
NY 2
E04 Terminal [X4] Function 2 (1002): Select multi-frequency (
SS4
)
㧙㧙
NY 7
E05 Terminal [X5] Function 3
(
1003
)
: Select multi-frequenc
y
(
SS
8
)
㧙㧙
NY 8
4 (1004): Select ACC/DEC time
(
RT1
)
6 (1006): Enable 3-wire operation (
HLD
)
7
(
1007
)
: Coast to a stop
(
BX
)
8 (1008): Reset alarm (
RST
)
9 (1009): Enable external alarm trip (
THR
)
10 (1010): Ready for jogging (
JOG
)
11 (1011): (
Hz2/Hz1
)
12 (1012): Select motor 2/motor 1 (
M2/M1
)
13 : Enable DC braking (
DCBRK
)
14 (1014): Select torque limiter level (
TL2/TL1
)
17 (1017): (
UP
)
18
(
1018
)
:
(
DOWN
)
19 (1019): (
WE-KP
)
20 (1020): Cancel PID control (
Hz/PID
)
21 (1021): (
IVS
)
24 (1024): (
LE
)
25 (1025): Universal DI (
U-D
I
)
26 (1026): (
STM
)
27 (1027): (
PG/Hz
) *5
30 (1030): Force to stop (
STOP
)
33 (1033): (
PID-RST
)
34 (1034): Hold PID integral component (
PID-HLD
)
42 (1042): *5
43 (1043): (
S/
R
) *5
44 (1044): (
SPRM
) *5
45 (1045): (
RT
N
) *5
46
(
1046
)
:
(
OLS
)
*5
E10 Acceleration Time 2 0.01 s Y Y 10.0 5-22
E11 Deceleration Time 2 0.01 s Y Y 10.0
E16 1% Y Y 999
E17 (Limiting level for braking) 1% Y Y 999
5-36
Enable auto search for idling
motor speed at starting
20 to 200
999 : Disable
Select frequency command 2/1
DOWN
(
Decrease out
p
ut
Name
Enable communications link via
RS-485 or field bus
Data setting range
20 to 200
999 : Disable
A
ctivate the limit switch at start p
o
Enable overload stop
Start/reset
Switch to the serial pulse
receiving
Reset PID integral and
differential components
Switch to speed feedback
Enter the return mode
Selecting function code data assigns the corresponding function to
terminals [X1] to [X5] as listed below.
Setting the value of 1000s in parentheses ( ) shown above assigns a
negative logic input to a terminal.
Torque Limiter 2
(Limiting level for driving)
Note: In the case of
THR
and
STOP
, data (1009) and (1030) are for normal
logic, and "9" and "30" are for negative logic, respectively.
UP (Increase output frequency)
Enable data change with keypad
Switch normal/inverse operation
0.00 to 3600
Note: Entering 0.00 cancels the acceleration time, requiring external soft-
start and -stop.
0.00 to 3600
Note: Entering 0.00 cancels the acceleration time, requiring external soft-
start and -stop.
*
5
These are available on inverters with inverter's ROM version 0700 or later. (For the version checking procedure, refer to
Chapter 3, Section 3.4.6 "Reading maintenance information."
)