5-4
(E codes continued)
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
E20 Terminal [Y1] Function
㧙㧙
NY 05-48
E21 Terminal [Y2] Function 0 (1000): Inverter running (
RUN
)
㧙㧙
NY 7
E27 Terminal [30A/B/C] Function 1 (1001): Frequency arrival signal (
FAR
)
㧙㧙
NY 99
2 (1002): Frequency detected (
FDT
)
3 (1003): (
LU
)
4 (1004): Torque polarity detected (
B/D
)
5
(
1005
)
: Inverter output limitin
g
(
IOL
)
6 (1006): (
IPF
)
7 (1007): (
OL
)
10
(
1010
)
: Inverter read
y
to run
(
RDY
)
21 (1021): Frequency arrival signal 2 (
FAR2
)
22 (1022): (
IOL2
)
26 (1026): Auto-resetting (
TRY
)
27 (1027): (
U-DO
) *6
28 (1028): (
OH
)
30 (1030): Service lifetime alarm (
LIFE
)
33
(
1033
)
: Reference loss detected
(
REF OFF
)
35 (1035): Inverter output on (
RUN2
)
36 (1036): Overload prevention control (
OLP
)
37 (1037): Current detected (
I
D
)
38 (1038): Current detected 2 (
ID2
)
42
(
1042
)
: PID alarm
(
PID-ALM
)
49 (1049): Switched to motor 2 (
SWM2
)
56 (1056): (
THM
) *6
57 (1057): Brake signal (
BRKS
)
59 (1059): (
C1OFF
) *6
76 (1076): (
PG-ER
R
) *5
80 (1080): (
OT
) *5
81 (1081): (
TO
) *5
82 (1082): (
PSET
) *5
83 (1083): (
POF
) *5
99
(
1099
)
:
A
larm output
(
for an
y
alarm
)
(
ALM
)
E29 Frequency Arrival Delay Time 0.01 to 10.00 0.01 s Y Y 0.10 5-52
E30 0.0 to 10.0 0.1 Hz Y Y 2.5
E31 0.0 to 400.0 0.1 Hz Y Y 60.0 -
E32
(
H
y
steresis width
)
0.0 to 400.0 0.1 Hz Y Y 1.0
E34 5-52
(Level) 0.01 A Y Y1
Y2
E35 (Timer) 0.01 to 600.00 *1 0.01 s Y Y 10.00
E37 0.01 A Y Y1
Y2
E38 (Timer) 0.01 to 600.00 *1 0.01 s Y Y 10.00
E39 0.000 to 9.999 0.001
Y Y 0.000 5-53
Positioning completed
Current position count overflowe
d
Terminal [C1] wire break
0.00 : Disable
Current value of 1 to 200% of the inverter rated current
Heat sink overheat early warning
Universal DO
Motor overheat detected by
thermistor (PTC)
Selecting function code data assigns the corresponding function to
terminals [Y1], [Y2], and [30A/B/C] as listed below.
Undervoltage detected
(Inverter stopped)
*4
Setting the value of 1000s in parentheses ( ) shown above assigns a
negative logic input to a terminal.
Current Detection 2ޓ (Level)
(
Detection level
)
Coefficient for Constant Feeding Rate
Time
Frequency Arrival
(Hysteresis width)
Fre
q
uenc
y
Detection
(
FDT
)
Overload Early Warning/Current
Detection
Auto-restarting after momentary
power failure
*4
Name Data setting range
Motor overload early warning
0.00 : Disable
Current value of 1 to 200% of the inverter rated current
Inverter output limiting with delay
PG error detected
Stop position override alarm
Timer output
*
1
When you make settings from the keypad, the incremental unit is restricted by the number of digits that the LED monitor can
display.
(Example) If the setting range is from -200.00 to 200.00, the incremental unit is:
"1" for -200 to -100, "0.1" for -99.9 to -10.0 and for 100.0 to 200.0, and "0.01" for -9.99 to -0.01 and for 0.00 to 99.99.
*
4
Default settings for these function codes vary depending on the inverter capacity. See Table 5.1 "Factory Defaults According
to Inverter Capacity" on pages 5-15 and 5-16.
*
5
These are available on inverters with inverter's ROM version 0700 or later. (For the version checking procedure, refer to
Chapter 3, Section 3.4.6 "Reading maintenance information."
*
6
These are available on inverters with inverter's ROM version 0800 or later. (For the version checking procedure, refer to
Chapter 3, Section 3.4.6 "Reading maintenance information."
)
)