Loading...
5-8
P codes: Motor 1 Parameters
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer to
page:
P01 2 to 22 2poles N Y1
Y2
45-56
P02 (Rated capacity) 0.01
0.01
kW
HP
NY1
Y2
*4
P03 (Rated current) 0.00 to 100.0 0.01 A N Y1
Y2
Rated value
of Fuji
standard
motor
P04 (Auto-tuning) 0: Disable
㧙㧙
NN 0
1:
2:
P05 (Online tuning) 0: Disable
㧙㧙
YY 0
1: Enable
P06 (No-load current) 0.00 to 50.00 0.01 A N Y1
Y2
Rated value
of Fuji
standard
motor
P07 (%R1) 0.00 to 50.00 0.01 % Y Y1
Y2
Rated value
of Fuji
standard
motor
P08 (%X) 0.00 to 50.00 0.01 % Y Y1
Y2
Rated value
of Fuji
standard
motor
P09 (Slip compensation gain for driving) 0.0 to 200.0 0.1 % Y* Y 100.0 5-57
P10 (Slip compensation response time) 0.01 to 10.00 0.01 s Y Y1
Y2
0.50
P11 (Slip compensation gain for braking) 0.0 to 200.0 0.1 % Y* Y 100.0
P12 (Rated slip frequency) 0.00 to 15.00 0.01 Hz N Y1
Y2
Rated value
of Fuji
standard
motor
5-56
P99 Motor 1 Selection 0:
㧙㧙
N 0 5-57
1: Motor characteristics 1 (HP rating motors)
3:
4: Other motors
Enable (Tune %R1, %X and rated slip while the motor is stopped, and
no-load current while running.)
Data setting range
0.01 to 30.00 (where, P99 data is 0, 3, or 4.)
0.01 to 30.00 (where, P99 data is 1.)
Enable (Tune %R1 and %X while the motor is stopped.)
Motor characteristics 0 (Fuji standard motors, 8-series)
Motor characteristics 3 (Fuji standard motors, 6-series)
Motor 1 (No. of poles)
Name
Y1
Y2
The shaded function codes ( ) are applicable to the quick setup.
*
4
Default settings for these function codes vary depending on the inverter capacity. See Table 5.1 "Factory Defaults According
to Inverter Capacity" on pages 5-15 and 5-16.