EasyManua.ls Logo

Fuji Electric FRENIC-Multi - Page 96

Fuji Electric FRENIC-Multi
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-13
(J codes continued)
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
J73 Positioning Control (Start timer) *5 0.0 to 1000.0 0.1 s Y Y 0.0 -
J74 (Start point; upper digits) *5 -999 to 999 1 p Y Y 0
J75 (Start point; lower digits) *5 [P], 0 to 9999 *7 1 p Y Y 0
J76 (Preset point; upper digits) *5 -999 to 999 1 p Y Y 0
J77 (Preset point; lower digits) *5 [P], 0 to 9999 *7 1 p Y Y 0
(Creep speed SW point;
upper digits) *5
(Creep speed SW point;
lower digits) *5
J80 (Creep speed) *5 0 to 400 1Hz Y Y 0
J81 (End point; upper digits) *5 -999 to 999 1 p Y Y 0
J82 (End point; lower digits) *5 0 to 9999 1 p Y Y 0
J83 (Positioning allowance) *5 0 to 9999 1 p Y Y 0
J84 (End timer) *5 0.0 to 1000.0 0.1 s Y Y 0.0
J85 (Coasting compensation) *5 0 to 9999 1 p Y Y 0
J86 (End point command) *5
㧙㧙
YY 0
J87 (Preset positioning requirement) *5 0, 1, 2
㧙㧙
NY 0
J88 (Position detection direction) *5 0, 1
㧙㧙
NY 0
P (Gain) *5
J91 I (Integral time) *5 0.001 s Y Y 999
J92 (Level adjustment) *5 0.1 % Y Y 100.050.0 to 150.0
YJ78 0 to 999 10
J79 0 to 9999
J90
Y0
Y
pY
1p Y
0, 1
Overload Stop Function 0.000 to 2.000, 999
0.001 to 9.999, 999
0.001 999Y
Name Data setting range
*
5
These are available on inverters with inverter's ROM version 0700 or later. (For the version checking procedure, refer to
Chapter 3, Section 3.4.6 "Reading maintenance information."
*
7
[P]: Current position (Absolute position)
Switching between "0" and [P] requires the simultaneous keying: + keys from "0" to [P] and +
keys from [P] to
"0."
)