6. SYSTEM DESIGN
COMPLETION OF FUNCTION SETTING MODE
6) To clear the function setting mode and return to the regular display, hold down the three
buttons "SET TEMP. V", "SET TEMP.  and "FAN" at the same time.
Normal mode display
*If no key entry is made for 60 seconds, even though none of the above buttons is pressed,
the function setting mode will automatically be cleared.
(If the function setting mode is automatically cleared while setting addresses, activate the
mode again according to the procedure in step 2.)
SETTING UP EACH INDOOR UNIT
Repeat the procedures in steps 1) through 6), and set up the indoor units requiring function
setting.
RESET THE POWER AFTER SETTING UP FUNCTION OF ALL
INDOOR UNITS
Important
If the reset is not performed, function settings cannot be read in normally.
After all the functions have been set, the circuit breaker needs to be switched off
for at least 2 minutes.
After the 2 minutes has passed, power can be restored.
The set function is stored in the PCB and will remain in memory even when the
power is turned off.
However, the settings are only effective after the power is reset.
Record the function settings of the indoor unit on a label, etc., and afx the label to
the unit so it can be used for after-sales service operations.
- (06 - 76) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG12LMCA and is the answer not in the manual?

Fujitsu ASHG12LMCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-split-
Product colorWhite
Dehumidifying capacity1.8 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3900 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)5300 W
Cooling capacity in watts (nominal)3400 W
Cooling energy efficiency (EER, W/W)3.5
Heating energy efficiency (COP, W/W)3.92
Seasonal efficiency rating (cooling) (SEER)7
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)4000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Power consumption (cooling) (max)970 W
Power consumption (heating) (max)1020 W
Annual energy consumption (cooling)170 kWh
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1225 kWh
Indoor unit typeWall-mountable
Indoor unit depth203 mm
Indoor unit width840 mm
Indoor unit height268 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
Outdoor unit depth293 mm
Outdoor unit width663 mm
Outdoor unit height535 mm
Outdoor unit weight26000 g
Outdoor unit noise level50 dB
Airflow750 m³/h