6. SYSTEM DESIGN
CHECK RUN CHECK ITEMS AND PROCEDURE6-2.
Use the following procedure to perform the Check run.
Check Item Procedure When an Error Occurs
1. Turn on
power
1.1 Check
communi-
cations
he power is on to the outdoor unit
connected branch boxes, and indoor units.
utoatica deterined ater the power is
turned on.
  he deterination taes about  inutes.
(During this time, the outdoor unit 7 seg.
displays are all lit.)
he deterination is pass i a  seg. dispas
of the outdoor unit turn off.
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
<All lit state> <All off state>
When an error occurred
 he nuber o error is autoatica dispaed.
 he error codes can be checed using the  button.
ter checing the error code turn o the power and resoe the probe.
[Ex] When a branch box error and serial signal error occurred (error during
operation).
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
<Displays the number of error> <Displays error code>
Press ENTER
button
The error code switches each time
the SELECT button is pressed.
1.2 Compressor
preheat
operation
he power is on to the outdoor unit
connected branch boxes, and indoor units.
ter the power is turned on preheating o the
compressor starts automatically. (Conduct
preheating for at least 12 hours.)
onr that a the outdoor unit  seg.
displays are off. (If there is an indoor unit,
branch box, or outdoor unit error, preheating
of the compressor will not be performed.)
[Caution]
If the power has been off for more than 6 hours, preheat the compressor for
at least 12 hours before conducting the Check run.
When an error occurred
 he nuber o error is autoatica dispaed.
 he error codes can be checed using the  button.
ter checing the error code turn o the power and resoe the probe.
 urn the power on again.
2. Check run 2.1 Check the
number of
connected
units
ontinue pressing the  button or
more than 3 seconds to begin checking the
number of connected units.
ter the nuber o connected units is shown
in the outdoor unit 7 seg. display, check if the
number of installed branch boxes and indoor
units has been detected correctly.
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
<All off state> <Number of units display>
Number of
Branch boxes
Number of
Indoor units
If the number of displayed units does not match the number of
installed units
If the number of units displayed by the outdoor unit indicators does not
match the number of installed branch boxes and indoor units, recheck the
wiring work and perform the Check run again.
2.2 Check
connected
positions
ontinue pressing the  button or
more than 3 seconds to begin operation to
check the connected positions.
he deterination taes about  hour. uring
this time the outdoor unit 7 seg. display will
show "C.rUn".)
he deterination is pass when nd is
displayed on the outdoor unit 7 seg. display.
Ex) mode: HEAT, 6 indoor units
H: HEAT, C: COOL
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
<Check run start>
<Check run
ends normally>
Check run has been completed. Please
conduct the test run.
Wiring Mistake Case 1
Connection destination does not
match
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
[Display Explanation]
The wire connected to Terminal A
of Branch box1 (left 2-digit) must be
rewired to Terminal B of Branch box
3 (right 2-digit).
[Caution]
The displayed wiring mistake
positions are displayed by the
indicators in order. Make a note of
all of them before turning off the
power and rewiring.
Wiring Mistake Case 2
Problem with the wiring or piping
connection
or
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
[Display Explanation]
Recheck how the wiring and piping
are installed.
(The number of wires and pipes does
not match.)
State in which automatic determination cannot be conducted
LED961 LED962
LED981
POWER
MODE
LED982
ERROR
is displayed
This shows the state in which automatic determination of whether there
are error positions during operation for the 2.2 Check connected positions
cannot be conducted.
In this case, press the MODE/EXIT button to end the Check run.
Since automatic determination is not possible, visually inspect the wiring
and piping and then conduct the test run.
Stopping Check run  hen ou want to stop hec run beore it is copeted press the  button whie .rn is dispaed.
hen hec run has been stopped beore it is copeted the sste is not in a state where it wi run nora.
Perform Check run again.
- (06 - 98) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG12LMCA and is the answer not in the manual?

Fujitsu ASHG12LMCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-split-
Product colorWhite
Dehumidifying capacity1.8 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3900 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)5300 W
Cooling capacity in watts (nominal)3400 W
Cooling energy efficiency (EER, W/W)3.5
Heating energy efficiency (COP, W/W)3.92
Seasonal efficiency rating (cooling) (SEER)7
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)4000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Power consumption (cooling) (max)970 W
Power consumption (heating) (max)1020 W
Annual energy consumption (cooling)170 kWh
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1225 kWh
Indoor unit typeWall-mountable
Indoor unit depth203 mm
Indoor unit width840 mm
Indoor unit height268 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
Outdoor unit depth293 mm
Outdoor unit width663 mm
Outdoor unit height535 mm
Outdoor unit weight26000 g
Outdoor unit noise level50 dB
Airflow750 m³/h