6. SYSTEM DESIGN
When function setting is in "Operation/Stop" mode
Operation
Stop
ON
OFF
Input signal
Indoor unit
When function setting is in "Forced stop" mode
Remote controller
ON ON ON
Input signal
ON
OFF
Indoor unit
Operation
Stop
Command
Forced stop
Normal
Remote control
operation invalidity
Parts (Optional)
Compact
Cassette
Slim Duct
Wall Mounted
Floor /
Ceiling
Floor
LJ LU / LM LF
Parts name External connect kit
Model name UT Y-XWZX UTD-ECS5A UTY-X WZX UTY-XWZ XZ5 UTY-XWZX
Compact
Cassette
Slim Duct
Wall Mounted
Floor /
Ceiling
Floor
LJ LU LM LF
Parts name - - Communication kit - - -
Model name - - UTY-XCBX Z1 UTY-TWBXF UTY-XCBX Z2 - - -
*For operating the EXTERNAL INPUT function, the wall mounted type (LJ, LU, LM) requires the communication kit
(UTY-XCBXZ1, UTY-TWBXF, UTY-XCBXZ2) in addition to the wire (UTY-XWZX, UTY-XWZXZ5).
(UTY-XWZX) (UTD-ECS5A) (UTY-XWZ XZ5)
- (06 - 114) -
SYSTEM
DESIGN
SYSTEM
DESIGN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASHG12LMCA and is the answer not in the manual?

Fujitsu ASHG12LMCA Specifications

General IconGeneral
TypeSplit system
TimerYes
Multi-split-
Product colorWhite
Dehumidifying capacity1.8 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity in watts (max)3900 W
Cooling capacity in watts (min)900 W
Heating capacity in watts (max)5300 W
Cooling capacity in watts (nominal)3400 W
Cooling energy efficiency (EER, W/W)3.5
Heating energy efficiency (COP, W/W)3.92
Seasonal efficiency rating (cooling) (SEER)7
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)4000 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4
AC input voltage230 V
AC input frequency50 Hz
Design load (cooling)- kW
Energy efficiency class (cooling)A++
Power consumption (cooling) (max)970 W
Power consumption (heating) (max)1020 W
Annual energy consumption (cooling)170 kWh
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)1225 kWh
Indoor unit typeWall-mountable
Indoor unit depth203 mm
Indoor unit width840 mm
Indoor unit height268 mm
Indoor unit weight8500 g
Indoor unit noise level (high speed)43 dB
Outdoor unit depth293 mm
Outdoor unit width663 mm
Outdoor unit height535 mm
Outdoor unit weight26000 g
Outdoor unit noise level50 dB
Airflow750 m³/h