4. Connection and Settings
Connecting Cascade Cables
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Copyright 2019 FUJITSU LIMITED P3AM-8012-14ENZ0
51
Connecting Cascade Cables
When two power synchronized units are cascaded, use the cascade cable to connect the power synchronized
units.
Cascade cables must be purchased separately.
A connection figure for the cascade cable is shown below.
Figure 15 Cascade cable connection
When the power synchronized units are cascaded, the unit that is connected to the server UPS unit is "power
synchronized unit#0".
Do not attach a branch connector or a termination resistor to the CASCADE port or the AC SENSOR port. Doing
so makes operations unstable.
CAUTION
Do
When connecting external (signal, power, etc.) cables, avoid placing stress on
them. Not doing so may damage the cables.
Do Not
Do not forcibly bend or fold the cable. Doing so may damage the cable and cause
the power synchronized unit to malfunction.
Power synchronized unit#1
Power synchronized unit#0
Server#0
UPS unit for
Server#0
Server#1
UPS unit for
Server#1
Cascade cable
(optional)
Power cord (for AC sensor)
AC SENSOR port
CASCADE port
SENSOR ports
90
Do not bend
more than 90 degrees
Do not fold