5. Adding a Connecting Device
Connection Procedure When Adding an ETERNUS DX/AF
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Copyright 2019 FUJITSU LIMITED P3AM-8012-14ENZ0
64
Connection Procedure When Adding an ETERNUS DX/AF
This section describes how to connect the power synchronized unit when an ETERNUS DX/AF is added.
For details about ETERNUS DX/AF installation, connection, and settings, refer to one of the following manuals:
ETERNUS AF S3 series All-Flash Arrays Configuration Guide (Basic)
ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
ETERNUS AF650 S2, ETERNUS AF650 All-Flash Arrays Configuration Guide (Basic)
ETERNUS DX200F All-Flash Arrays Configuration Guide (Basic)
ETERNUS DX S5 series Hybrid Storage Systems Configuration Guide (Basic)
ETERNUS DX60 S4/DX60 S3 Hybrid Storage Systems Configuration Guide (Basic)
ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Configuration Guide
(Basic)
ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Configuration Guide
(Basic)
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Installation-
ETERNUS DX60 S2 Disk storage system User's Guide -Installation-
Adding up to four ETERNUS DX/AF storage systems
The connection procedure when up to four ETERNUS DX/AF storage systems are added is described below.
Procedure
1 Set the required settings for power synchronization of the ETERNUS DX/AF storage systems that
are to be added.
For details about the ETERNUS DX/AF settings, refer to "Setting the ETERNUS DX/AF" (page 44).
2 Connect the ETERNUS DX/AF storage systems to the power synchronized unit.
An example of a connection between ETERNUS DX/AF storage systems and a power synchronized unit is
shown below.
For details about how to connect an ETERNUS DX/AF to the power synchronized unit, refer to "
Connecting to
the ETERNUS DX/AF" (page 57).
Adding the ETERNUS DX8900 S4 or ETERNUS DX8100 S3/DX8700 S3/DX8900 S3 must be performed by your
maintenance engineer. Do not attempt to add the ETERNUS DX8100 S3/DX8700 S3/DX8900 S3 by yourself.