EasyManua.ls Logo

Fujitsu MCM3064SS - Environmental and Power Requirements; Table 2.3 Environmental and Power Requirements

Fujitsu MCM3064SS
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Specifications
2-4 C156-E228-02EN
2.1.3 Environmental and power requirements
Table 2.3 lists the environmental and power requirements.
Table 2.3 Environmental and power requirements (1 of 2)
Item Specification
Power
requirements
Average +5 VDC±5% (*1), 1.2A (2.7A max)
Ripple requirement 100mV pp (DC-1 MHz)
Power Ready 3.9 W (typ) (*2)
consumption Random seek, read or write 6.1 W (typ) (*2)
(Average) Power save
mode
Pre-idle mode
Idle mode
Standby mode
Sleep mode
3.9 W (typ) (*2)
2.0 W (typ) (*2)
1.2 W (typ) (*2)
1.2 W (typ) (*2)
Outer
dimensions
With panel 101.6×150.0×25.4 mm
(W × D × H) Without panel 101.6×148.4×25.4 mm
Weight 410 g (with panel)
Environmental
requirements
Operating Temperature: 5 to 45°C (gradient 15°C /h or less)
(*3)
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 29°C or lower
Idle Temperature: 0 to 50°C
Relative humidity: 10 to 85% (No condensation)
Maximum wet bulb temperature: 36°C or lower
Transport Temperature: –40 to 60°C (24 hours or less)
Temperature: –20 to 60°C (24 hours or more)
Relative humidity: 5 to 90% (No condensation)
Maximum wet bulb temperature: 41°C or lower
Installation Tilt angle –5° to +10° (*3)

Table of Contents