BX900S2 Operating Manual 71
Starting up and operation
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that
requires (precautionary) service intervention.
Flashes orange if an error was detected that requires service
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the Management Blade Web interface, on the
ServerView Local Service Panel, on the ServerView Local Service
Display, in the ServerView Operations Manager or via the
iRMC S2/S3's Web interface.
CSS CSS indicator (yellow)
Lights up yellow if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of precaution)
with the CSS concept.
Flashes yellow if an error was detected that you can fix yourself
with the CSS concept.
Does not light up when the system is OK.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
For more information on the CSS concept, see "Customer Self
Service (CSS)" on page 11.
ID ID indicator (blue):
Glows blue when the system was selected by pressing the ID
button. Pressing the button again deactivates the LED.
The ID indicator can also be activated via the Management Blade
Web interface and via the ServerView Operations Manager and the
iRMC S2/S3 Web interface and its status reported to the
ServerView Operations Manager and the iRMC S2/S3.
!