EasyManua.ls Logo

Fujitsu PRIMERGY BX900 - Connecting the Embedded Switch Module through an External Port

Fujitsu PRIMERGY BX900
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26 Brocade 5450 Hardware Reference Manual
53-1001266-02
Connecting the Embedded Switch Module to the Ethernet network
3
Connecting the Embedded Switch Module through an external port
Use the following procedure to establish an Ethernet connection through an external port.
NOTE
Ensure that the Embedded Switch Module is not being modified from any other connection until
configuration is complete.
1. Connect an Ethernet cable to the Management LAN port on the Embedded Switch Module
faceplate.
2. Click Connection Blades Status in the middle pane of the PRIMERGY BX900 Management
Blade GUI to expand the list.
3. Select FC Connection Blade from the Connection Blade Status in the middle pane, shown in
Figure 11,
FIGURE 11 PRIMERGY BX900 Management Blade application - FC connection blade
The current FC Connection Blade information displays.
4. Click the Configuration tab in the middle pane.
5. Scroll down to the Management Port Control section, shown in Figure 12.
FIGURE 12 PRIMERGY BX900 Management Blade application - management port control
6. Select External Port from the Management Port list.
7. Cl ic k Apply.
NOTE
Refer to the PRIMERGY BX900 Management Blade User Guide for additional details.

Table of Contents

Other manuals for Fujitsu PRIMERGY BX900

Related product manuals