A
Facility requirements
The information in Table 10 shows the operating and non-operating limitations of the Embedded
Switch Module.
Electrical
Table 11 lists Embedded Switch Module electrical specifications.
TABLE 10 Embedded Switch Module environmental requirements
Condition Operating Non-operating
Temperature 0°C to 40°C (32°F to 104°F) -20°C to 70°C (-4°F to 158°F)
Humidity 10% to 90%, non-condensing at
29°C (84.2°F)
5% to 95%, non-condensing at
38°C (100.4 °F)
Altitude Up to 3,048 m (10,000 ft) 10,668 m (35,000 ft)
Shock 20 G for 6 ms 80G with velocity change of 4572
mm/sec squared
Vibration 0.4 G at 5-500 Hz for 60 minutes 0.5 G at 2-200 Hz for 15 minutes;
1.04 GRMS Random for 15 minutes
Air flow 30°C (86 °F) Ambient: Approx.
3CFM
40°C (104°F) Ambient: Approx.
9CFM
None required
TABLE 11 Embedded Switch Module electrical specifications
Dimension Measurements
DC input 12 V and 3.3 V from chassis
Power consumption Approximately 35 watts nominal and 50 watts maximum