38 Options Guide RX300 S3
Replacing the processor Processors
Ê Place the heat sink on the processor.
Ê Fasten the heat sink by tightening the four screws in a crossover pattern.
V CAUTION!
Never install a processor without a heat sink as otherwise the processor
may overheat, causing a shut-down of the system.
Ê Reinstall the ventilation duct over the memory and processors.
V CAUTION!
Ensure a correct fit of the airduct and that no damage is caused to the
cables
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 101.
6.2 Replacing the processor
V CAUTION
Only processors of the same type may be used on the system board. The
second processor must have the same clock frequency and the same
cache as the first processor. For dual operation, use a suitable multipro-
cessor operating system.
Ê Open the server as described in the chapter “Preparation” on page 21.