30 Service Supplement TX150 S6
Replacing the processor Replacement routines
Ê Pull the first removed intrusion switch out of the cable clamp.
V CAUTION!
Note the cable routing.
Ê Remove the intrusion switch cable from the connector on the system board
(see also the Technical Manual of the system board).
Ê Plug the new intrusion switch cable to the connector on the system board.
Ê Route the intrusion switch cable.
Ê Position the intrusion switch with the three wires on the front cover and
fasten it with two screws.
Ê Insert the intrusion switch with the two wires in its holder and fasten the
switch with two screws.
Ê Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.9 Replacing the processor
V CAUTION!
Processors are modules which can react extremely sensitively to electro-
static discharges and which must therefore always be handled with care.
After a processor has been removed from its protective sleeve or from its
socket, place it with its smooth side down on a non-conducting, antistatic
surface. Never push a processor over a surface.
Ê Open the server as described in the section “Preparation” on page 17.