State
Ascending
Descending
Action
Level4
Shutdown
80℃~
75℃~
If the temperature exceeds over
85 , the device will shutdown
automatically.
Review the condition in/around the
device, improve the ventilation
condition of the device.
Level3
Critical
60℃~80
55℃~75
Check the environment
temperature, if it does not
complying with the operating
condition, take appropriate action
to meet the operating condition.
Review the condition in/around the
device, improve the ventilation
condition of the device.
Level2
Warning
45℃~60
40℃~55
No action is required.
This device may be in this state
when it is under high load or if the
environmental temperature
exceeds 30.
Level1
Normal
30℃~45
25℃~40
No action is required.
IDLE
Low
30
25
No action is required.
Table 4-1: Transitions of Device Temperature