Introduction
3
11. LAN connection: See page.7-70.
Use cross cables for the LAN connection between FAR and FAR, and FAR and
CU-200. For connection via HUB-10, either a cross cable or straight cable can be
used. HUB-100 has the Auto-MDIX function and automatically recognizes a cable.
Use cables of Category 5.
Straight Cable Cross Cable
Pear Pin No. Signal
Pin No. Signal Pin No. Signal
1
(White-Green)
TXP
1
(White-Green)
TXP
1
(3 White-Orange)
RXP
1-2
2
(Green)
TXN
2
(Green)
TXN
2
(6 Orange)
RXN
3-6
3
(White-Orange)
RXP
3
(White-Orange)
RXP
3
(1 White-Green)
TXP
4
(White-Blue)
NC
4
(White-Blue)
NC
4
(4 White-Blue)
NC
4-5
5
(Blue)
NC
5
(Blue)
NC
5
(5 Blue)
NC
3-6
6
(Orange)
RXN
6
(Orange)
RXN
6
(2 Green)
TXN
7
(White-Brown)
NC
7
(White-Brown)
NC
7
(7 White-Brown)
NC
7-8
8
(Brown)
NC
8
(Brown)
NC
8
(8 Brown)
NC
Note: To make the LAN cable, see the Operator’s Manual of HUB-100 for details.
1. Cut neatly except for the leaving 11 mm. Then, fold the shield and the drain wire of
the cable. Moreover, insert into the plug housing
2. Insert until you can find the edge of cable from the housing.
3. Use the crimping tool to finish.
Crimping
8 pins
1 pin
Crimp the drain wire.
Fold the shield and wind it to the external of the cable.
Fold the train line along with the shield.
And then,
Cut neatly except for the leaving 11 mm.
11 mm
shield and the drain wire