EasyManuals Logo

Galil Motion Control DMC-40x0 Series User Manual

Default Icon
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
34 AT DMC-40x0 Command Reference
AT
FUNCTION: At Time
DESCRIPTION:
The AT command is a trippoint which is used to hold up execution of the next command until
after the specified time has elapsed. The time is measured with respect to a defined reference
time. AT 0 establishes the initial reference. AT n specifies n msec from the reference. AT -n
specifies n msec from the reference and establishes a new reference after the elapsed time
period.
ARGUMENTS: AT n where
n is a signed, even integer in the range 0 to 2 Billion
n = 0 defines a reference time at current time
n > 0 specifies a wait time of n msec from the reference time
n < 0 specifies a wait time of n msec from the reference time and re-sets the reference time
when the trippoint is satisfied.
(AT -n is equivalent to AT n; AT <old reference +n>
USAGE: DEFAULTS:
While Moving Yes Default Value 0
In a Program Yes Default Format -
Command Line No
Controller Usage
ALL CONTROLLERS
EXAMPLES:
The following commands are sent sequentially
AT 0 Establishes reference time 0 as current time
AT 50 Waits 50 msec from reference 0
AT 100 Waits 100 msec from reference 0
AT -150 Waits 150 msec from reference 0 and sets new reference at 150
AT 80 Waits 80 msec from new reference (total elapsed time is 230 msec)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Galil Motion Control DMC-40x0 Series and is the answer not in the manual?

Galil Motion Control DMC-40x0 Series Specifications

General IconGeneral
BrandGalil Motion Control
ModelDMC-40x0 Series
CategoryController
LanguageEnglish

Related product manuals