3E2364WeighScaleW810v2UserManual
Page47
Fine
Finemodeisrecommendedforweighingstaticloadssuchasfleecesorproduce.
InFinemode,theWeighScaledisplaystheweightontheplatforminthesame
wayasabathroomscale.
Ifaweightmeasurementistobeaddedtothesessionstatistics,theoperator
pressesthegreenweighbutton.Theweightiscapturedatthispoint,butitis
notstoredintheweightrecorduntiltheweightisremovedfromtheplatform.
Aftertheweighthasbeencaptured,thestatisticsareupdated.Forinformation
aboutstatistics,seeSessionstatistics(p39).Thedisplayedweightcontinuesto
reflectthe
actualweightontheplatform.
InFinemode,automaticzerotrackingisswitchedoff.ThismeanstheWeigh
Scaledoesnotautomaticallycompensatefortheweightofobjectsleftonthe
platformaftertheloadhasbeenremoved.Formoreinformation,seeZero
tracking(p87).
Thebluezero
buttonhasafunctioninFinemodeifyouwanttomakenet‐weight
measurementsofaloadinsideacontainer.Forexample,youcouldplacean
emptycontainerontheweighingplatformandpressthebluezerobutton.If
youthenfilledthecontainer,theweightindicationwillbeonlythatofthe
container'scontents.
Note:InFinemode,afterthebluezerobuttonhasbeenpressed,theweightindication
showszerobutthe icondoesnotdisplay.