AFTERCOOLER (DOMESTIC)
I I
Water Temperature to Heat Exchanger
Gallons/minute
HP Model 600 F.
70° F. 80° F, 90° F.
40 HP EBHSHA
.5 .7 .9 1.3
40 HP
EBHSHB .5 .7 .9
1,3
50 HP EBHSJA .7 .9
1.2 1.8
50 HP EBHSJB .7 .9 1.2
1.8
60 HP
EBMSKA
.8
1.0 1.4
2.1
60 HP
EBMSKC .8 1.0 1.4
2.1
75 HP EBMSIA 1.2
1,5 2.0 3.0
75 HP EBMSLC
1.2
1.5 2.0
3.0
100 HP EBPSMA 1.7 2.1 2.8
4.1
100 HP EBPSMB 1.7
2.1 2.8
4.1
100 HP EAPSMC 1.7
2.1 2.8 4.1
Maximum
Water Flow
GPM*
Approx.
Water Pressure
Drop @ 90° F
Water Temp.
Psl
26.0
26.0
26.0
3
26.0
Less than 1 PSI
26.0
26.0
for any flow rate
26.0
shown in the table.
26.0
I
26.0
26.0
26.0
AFTERCOOLER (INTERNATIONAL)
Water Temperature to Heat Exchanger
Liters/Second
Maximum
Water Flow
Kw Model 16° C.
210 c. 27° C.
32° C. L/s *
45 Kw EBMSKB .05 ,06 .09
.13
1.64
55 Kw EBMSLB ,08 .09 ,13
.19
1.64
75 Kw EBMSMB .11 .13 .18
.26
1.64
Approx.
Water Press. Drop
@ 32° C. Water
Temp. Bar
Less than .1 Bar
for any flow rate
shown in the table.
* Flows exceeding “Maximum Water Flow" will cause severe erosion and will void unit warranty,
FIGURE 2-6- AFTERCOOLER APPROXIMATE WATER FLOW
Accessibility for inlet air filter servicing must be consid-
ered when relocating the filters from the unitto a remote
location,
DISCHARGE SERVICE LINE - The discharge service
line connection on both water-cooled and air-cooled
units is made at the right hand corner of the unit, viewed
from the opposite end from control panel side. When
manifolding two or more rotary screw units on the same
line, each unit is isolated by the check valve in the unit
discharge line. If a rotary screw unit is manifolded to
another compressor, be sure the other compressor has
a check valve in the line between the machine and the
I
~DANGER
Discharge air used for breathing will
cause severe injury or death.
Consult filtration specialists for addi-
tional filtration and treatment equip-
ment to meet health and safety stan-
dards.
manifold. If a rotary screw and a reciprocating com-
BLOWDOWN VALVE PIPING - The blowdown valve
pressor are manifolded together, an air receiver must
isfitted with a muffler for operation indoors. Ifthe instal-
be located between the two units. Iation requires, the muffler may be removed and the
13-9/10-641 Page 12

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gardner Denver EBMQLC and is the answer not in the manual?

Gardner Denver EBMQLC Specifications

General IconGeneral
BrandGardner Denver
ModelEBMQLC
CategoryCompressor
LanguageEnglish

Related product manuals