ELECTRIC MOTOR GREASE RECOMMENDATIONS (-30° to 50° C)
MANUFACTURER
I
TRADE NAME
CHEVRON
SRI #2
SHELL
DOLIUM R
EXXON
UNIREX #2
EXXON
POLYREX
ELECTRIC MOTOR REGRESSING INTERVAL
Relubrication
Type of Service
Typical Examples
Rating
Interval
150 HP(112KW)
18 Months
Standard
One- or Two-Shift Operation
Above 150 HP (112 KW)
12 Months
150 HP(112KW)
9 Months
Severe
Continuous Operation
Above 150 HP (112 KW)
6 Months
150HP (112 KW)
4 Months
Very Severe Dirty Locations, High
Ambient Temperature
Above 150 HP (112 KW)
2 Months