SYMPTOM
POSSIBLE CAUSE REMEDY
Oil Carry-Over (Continued)
7, Operation atelevated
7,
discharge temperatures.
8. Scavenge line check
8.
valve failure.
9. Water condensate in oil.
9.
Reduce temperature. See
High Discharge Air
Temperature, page 59,
this section.
Replace check valve.
Check oil reservoir tempera-
ture and if low, change”
thermal mixing valve element
to higher temperature.
I
NOTICE
I
Gardner Denver factory remanufactured replacement compressor air end units
are available from your authorized distributor, on an exchange basis, for all rotary
screw compressor units.
13-9/10-641 Page 60