Regularly clean and maintain your machine according to our cleaning and maintenance instructions. Doing
so will ensure a machine that will operate effectively and safely over a long period of time.
1.6 Operating Environment
Please follow the guidelines when considering a suitable location to set the LaserPro C180. Improper work
environments may lead to operational malfunction and/or unsafe working conditions. The LaserPro C180
should be placed and operated in a standard ofce-type environment.
• Avoid environments where the machine is exposed to high levels of dust, temperature
(temperatures exceeding 30°C or 85°F) or humidity (humidity exceeding 70% or where the
ambient temperature is near the dew point).
• Avoid small, enclosed areas with poor ventilation.
• Avoid areas with high levels of noise and electrical noise.
• Select a location that is large enough to accommodate the LaserPro C180, an exhaust system,
a computer and a work or storage table.
• Select a location in which the ambient temperature remains between 15°C and 30°C
(60°F to 85°F).
• Select a location in which the relative humidity remains between 30% - 40%.
• Select a location in which there is a short, direct path to the fume exhaust system.
• Set the LaserPro C180 on a oor surface that is completely even.
• Make sure your smoke or re detection system in the immediate area is functioning.
• Setup the machine to be at least 60 cm (2 feet) away from the wall.
NOTE
SmartGUARD™ is an optional re detection alarm system developed by GCC. Contact
your local GCC authorized distributor for more details for having this safety option installed
onto your system.