September 2004
2-4 Programming Site Data
Entering Transducer and
Pipe Parameters
[CHx-PIPE Menu]
Enter the transducer and pipe parameters via the PIPE submenu (see
Figure A-1 on page A-1).
Accessing the PIPE
Submenu
1. Press [ESC], [ENTER], [ESC] in sequence to enter the user program.
2. Press [
X] until PROG appears and press [ENTER].
3. Press [
X] until the desired channel appears. Press [ENTER] at CH1
or
CH2.
4. Press [
X] until PIPE appears and press [ENTER].
5. Do one of the following:
• For standard transducers, use the arrow keys to enter the
transducer number. Press [
W] and [X] to move the cursor to
the desired location and press
[S] and [T] to increase or
decrease the number. Then press
[ENTER] and proceed to the
next step.
• For special transducers, proceed to the next section.
6. Go to one of the following sections:
• Standard clamp-on transducers - proceed to Pipe Material on
page 2-6.
• Standard wetted transducers - proceed to Pipe Outside
Diameter on page 2-7.