September 2004
2-10 Programming Site Data
KV Input Selection 1. Press [W] and [X] to enter a static kinematic viscosity or a table of
values and press
[ENTER].
2. Do one of the following:
• If you selected Table, enter the Calibration Factor by using the
arrow keys. Press [
W] and [X] to move the cursor to the
desired location and press
[S] and [T] to increase or decrease
the number. Then press
[ENTER].
• If you selected STATC, the AT868 will select and automatically
display the Kinematic Viscosity (see note below). If you want
to enter a different number use the [
W] and [X] to move the
cursor to the desired location and press
[S] and [T] to
increase or decrease the number. Then press
[ENTER]. Enter the
Calibration Factor in a similar manner and press
[ENTER].
Note: If you select
OTHER as the fluid type, you must enter the
Kinematic Viscosity. The AT86 8 will only approximate the
Kinematic Viscosity if you select one of the specific available
fluid options.
3. Proceed to one of the following sections:
• Clamp-on Transducers - proceed to Number of Traverses and
Transducer Spacing below.
• Wetted Transducers - The meter returns to the Channel
PROGRAM
window. To complete initial setup of the AT868, you
must enter data in the
GLOBL-SYSTM submenu on page 2-12.
Number of Traverses and
Transducer Spacing
1. Press [W] and [X] to select the number of traverses and press
[ENTER].
2. Enter the value for the transducer spacing by using the arrow keys.
Press [
W] and [X] to move the cursor to the desired location and
press
[S] and [T] to increase or decrease the number. Then
press
[ENTER].