3300/25 Dual Accelerometer Input Monitor Operation Manual
102
Low Pass Filter Options (Continued)
W43
W56
W54
W57
W100
W200
W101
W201
W102
W202
W103
W203
Ch. A
Ch. B
R R I R R I
Ch. A
Ch. B
W47
W69
W48
W70
W49
W71
W50
W72
W51
W73
W52
W74
W53
W75
W55
W77
Hz CPM
274 16440 I I I R I I R I
282 16920 I R I R I I R I
289 17340 I I R R I I R I
297 17820 I R R R I I R I
305 18300 I I I I R I R I
313 18780 I R I I R I R I
321 19260 I I R I R I R I
329 19740 R I R I R I R I
337 20220 I I I R R I R I
344 20640 I R I R R I R I
360 21600 I R R R R I R I
368 22080 I I I I I R R I
376 22560 I R I I I R R I
384 23040 I I R I I R R I
392 23520 I R R I I R R I
399 23940 I I I R I R R I
407 24420 I R I R I R R I
415 24900 R I R R I R R I
423 25380 R R R R I R R I
431 25860 R I I I R R R I
439 26340 R R I I R R R I
446 26760 R I R I R R R I
454 27240 R R R I R R R I
462 27720 R I I R R R R I
470 28200 R R I R R R R I
478 28680 R I R R R R R I
486 29160 R R R R R R R I
493 29580 R I I I I I I R
501 30060 R R I I I I I R
509 30540 R I R I I I I R
516 30960 R R R I I I I R
R = REMOVE JUMPER, I = INSTALL JUMPER. This table is two pages wide.