Section 19 -  Appendix B–Filter Board Options PWA 79562-01 and PWA 105521-01 
 
63
19.8 Non Standard High Pass Filter Options 
Follow this procedure only if the desired high-pass corner frequency is not listed in the 
table in the previous section. 
 
1.  Select a high-pass corner frequency, f
hp
, in the range 3.7 Hz to 3008 Hz. 
 
2.  Select a value, K, according to this table: 
 
If your frequency is within 
this range, 
Use this value for K 
3.7 Hz to 318 Hz  1.246 
319 Hz to 3008 Hz  11.797 
 
3.  Calculate the multiplier value, D, by using this formula: 
 
 
K
f
=D
HP
 
where  
 
f
HP
 is the high-pass corner frequency from step 1 
K is the constant selected in step 2 
D is the multiplier value            (D should be in the range 3 to 255) 
 
4. Convert D to the closest 8 bit binary integer, D0 to D7. 
 
5.  Install/Remove jumpers according to the following table.  The jumpers 
corresponding to values D0 to D7 are installed according to these rules: 
 
an installed jumper  = 0,    D0 is the least significant bit (LSB) 
a removed jumper   = 1,    D7 is the most significant bit (MSB) 
CHANNEL 
K = 1.246 
 
REMOVE 
K = 11.797 
 
INSTALL 
   (MSB)                  (LSB) 
D7     D6       D5      D4      D3     D2     D1      D0 
A 
W11   W31 
W38   W40 
W11   W31 
W38   W40 
W18   W17   W16   W15   W14   W13  W12   W42 
B 
W23   W30 
W35   W36 
W23   W30 
W35   W36 
W19   W24   W25   W33   W34   W29   W32  W28