3300/25 Dual Accelerometer Input Monitor Operation Manual
106
Low Pass Filter Options (Continued)
W43
W56
W54
W57
W100
W200
W101
W201
W102
W202
W103
W203
Ch. A
Ch. B
R R I R R I
Ch. A
Ch. B
W47
W69
W48
W70
W49
W71
W50
W72
W51
W73
W52
W74
W53
W75
W55
W77
Hz CPM
759 45540 I R R I I I R R
767 46020 I I I R I I R R
775 46500 I R I R I I R R
782 46920 I I R R I I R R
790 47400 I R R R I I R R
798 47880 I I I I R I R R
806 48360 I R I I R I R R
814 48840 I I R I R I R R
822 49320 R R R I R I R R
830 49800 R I I R R I R R
837 50220 R R I R R I R R
845 50700 R I R R R I R R
853 51180 R R R R R I R R
861 51660 R I I I I R R R
869 52140 R R I I I R R R
877 52620 R I R I I R R R
885 53100 R R R I I R R R
892 53520 R I I R I R R R
900 54000 R R I R I R R R
908 54480 R I R R I R R R
916 54960 R R R R I R R R
924 55440 R I I I R R R R
931 55860 R R I I R R R R
939 56340 R I R I R R R R
947 56820 R R R I R R R R
955 57300 R I I R R R R R
963 57780 R R I R R R R R
971 58260 R I R R R R R R
979 58740 R R R R R R R R
R = REMOVE JUMPER, I = INSTALL JUMPER. This table is two pages wide.