EasyManuals Logo

GE Concord 4 Installation Manual

GE Concord 4
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
Chapter 3: Programming
Concord 4 Installation Manual 45
Keyfob PTN
Shortcut: 0006
Default: On
This feature controls which partitions the selected keyfob can
arm/disarm. When enabled, the selected keyfob can arm/disarm the
partitions selected in this menu. When disabled, the selected keyfob
cannot arm/disarm multiple partitions. For this feature:
• If no keyfobs are learned into panel memory, the menu displays NOT
AVAILABLE. When keyfobs are learned into panel memory, two
submenus appear. The first one lets you view keyfob assignments similar
to that of viewing learned sensors. The second submenu lets you view
and change the multipartition arming assignments for that keyfob.
• At least two partitions must be selected.
• Keyfobs can arm/disarm multiple partitions only for those partitions set
up in the Multipartition arm/disarm menu.
• A partition cannot be armed/disarmed if it is being controlled by anothe
r
source at that time.
• When arming multiple partitions from a keyfob, any conditions that
prevent arming are identified on touchpad displays in the partition where
that condition exists. Touchpad displays in all other partitions being
armed display PROTEST. The normal protest/auto force arm sequence
follows, or pressing * on any touchpad in a partition being armed cancels
the arming request. Pressing the Lock button again during a protest
bypasses any open sensors in the affected partitions and arms those
partitions.
• When disarming multiple partitions with a keyfob and alarms are active
in one or more of the assigned partitions, protest beeps sound for 5
minutes in all partitions being disarmed; partitions in alarm where sirens
have timed out sound protest beeps for 5 minutes; and partitions in alarm
with active sirens continue sounding the alarm.
In any case where alarms are active the premises may not be safe to
enter. The user has these options: leave and call for help from a safe
location; if entering the premises anyway, go to a hardwired touchpad
and check the system status to determine the alarm. Disarm and alarm
memory is displayed for all assigned partitions; and press the keyfob
Unlock button a second time (within the 5-minute protest period) to
disarm all assigned partitions and cancel all alarms, then go to a
hardwired touchpad and check alarm memory.
To enable keyfob PTN:
1. Learn all keyfobs into panel memory. (See “
Sensors menu” on page 65.)
2. Enter this menu (display showing KEYFOB TP PTN), then press #. The
display shows the lowest touchpad sensor number assignment such as:
S1 P1 G0 TP RF where S1 is sensor 1, P1 is partition 1, G0 is sensor
group 0, TP is touchpad and RF is wireless.
3. Press # to accept this keyfob or press A or B until the desired keyfob
appears, then press #. The display shows ARM PARTITION.
4. Enter the desired partitions 1 to 6 (at least two). The display flashes the
entered partitions.

Table of Contents

Other manuals for GE Concord 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Concord 4 and is the answer not in the manual?

GE Concord 4 Specifications

General IconGeneral
Zones96
Partitions6
User Codes230
Power Supply16.5 VAC, 40 VA
Wireless CompatibilityCompatible with GE wireless sensors
KeypadsUp to 8
Outputs2 onboard, expandable
Event Log512 events
Backup Battery12VDC, 7AH
CommunicationPhone line, optional cellular or IP

Related product manuals