EasyManuals Logo

GE T60 User Manual

GE T60
770 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
GE Multilin T60 Transformer Protection System v
TABLE OF CONTENTS
5.2.17 DIRECT INPUTS AND OUTPUTS................................................................... 5-92
5.2.18 TELEPROTECTION......................................................................................... 5-99
5.2.19 INSTALLATION.............................................................................................. 5-100
5.3 REMOTE RESOURCES
5.3.1 REMOTE RESOURCES CONFIGURATION................................................. 5-101
5.4 SYSTEM SETUP
5.4.1 AC INPUTS .................................................................................................... 5-102
5.4.2 POWER SYSTEM.......................................................................................... 5-104
5.4.3 SIGNAL SOURCES ....................................................................................... 5-105
5.4.4 TRANSFORMER ........................................................................................... 5-107
5.4.5 BREAKERS.................................................................................................... 5-120
5.4.6 DISCONNECT SWITCHES ........................................................................... 5-124
5.4.7 FLEXCURVES ............................................................................................... 5-127
5.4.8 PHASOR MEASUREMENT UNIT.................................................................. 5-134
5.5 FLEXLOGIC
5.5.1 INTRODUCTION TO FLEXLOGIC ................................................................ 5-157
5.5.2 FLEXLOGIC RULES ...................................................................................... 5-168
5.5.3 FLEXLOGIC EVALUATION ........................................................................... 5-168
5.5.4 FLEXLOGIC EXAMPLE ................................................................................. 5-169
5.5.5 FLEXLOGIC EQUATION EDITOR................................................................. 5-173
5.5.6 FLEXLOGIC TIMERS .................................................................................... 5-173
5.5.7 FLEXELEMENTS........................................................................................... 5-174
5.5.8 NON-VOLATILE LATCHES ........................................................................... 5-179
5.6 GROUPED ELEMENTS
5.6.1 OVERVIEW.................................................................................................... 5-180
5.6.2 SETTING GROUP ......................................................................................... 5-180
5.6.3 DISTANCE ..................................................................................................... 5-181
5.6.4 POWER SWING DETECT............................................................................. 5-201
5.6.5 LOAD ENCROACHMENT.............................................................................. 5-211
5.6.6 TRANSFORMER ELEMENTS ....................................................................... 5-213
5.6.7 PHASE CURRENT ........................................................................................ 5-223
5.6.8 NEUTRAL CURRENT.................................................................................... 5-234
5.6.9 GROUND CURRENT..................................................................................... 5-242
5.6.10 BREAKER FAILURE...................................................................................... 5-249
5.6.11 VOLTAGE ELEMENTS.................................................................................. 5-258
5.7 CONTROL ELEMENTS
5.7.1 OVERVIEW.................................................................................................... 5-269
5.7.2 TRIP BUS....................................................................................................... 5-269
5.7.3 SETTING GROUPS ....................................................................................... 5-271
5.7.4 SELECTOR SWITCH..................................................................................... 5-273
5.7.5 UNDERFREQUENCY.................................................................................... 5-279
5.7.6 OVERFREQUENCY ...................................................................................... 5-280
5.7.7 FREQUENCY RATE OF CHANGE................................................................ 5-281
5.7.8 SYNCHROCHECK......................................................................................... 5-283
5.7.9 DIGITAL ELEMENTS..................................................................................... 5-287
5.7.10 DIGITAL COUNTERS .................................................................................... 5-290
5.7.11 MONITORING ELEMENTS ........................................................................... 5-292
5.8 INPUTS AND OUTPUTS
5.8.1 CONTACT INPUTS........................................................................................ 5-310
5.8.2 VIRTUAL INPUTS.......................................................................................... 5-312
5.8.3 CONTACT OUTPUTS.................................................................................... 5-313
5.8.4 VIRTUAL OUTPUTS...................................................................................... 5-315
5.8.5 REMOTE DEVICES....................................................................................... 5-316
5.8.6 REMOTE INPUTS.......................................................................................... 5-317
5.8.7 REMOTE DOUBLE-POINT STATUS INPUTS .............................................. 5-318
5.8.8 REMOTE OUTPUTS...................................................................................... 5-318
5.8.9 RESETTING................................................................................................... 5-319
5.8.10 DIRECT INPUTS AND OUTPUTS................................................................. 5-320
5.8.11 TELEPROTECTION INPUTS AND OUTPUTS.............................................. 5-323
5.8.12 IEC 61850 GOOSE ANALOGS...................................................................... 5-325
5.8.13 IEC 61850 GOOSE INTEGERS..................................................................... 5-326
5.9 TRANSDUCER INPUTS AND OUTPUTS
5.9.1 DCMA INPUTS .............................................................................................. 5-328
5.9.2 RTD INPUTS.................................................................................................. 5-329

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE T60 and is the answer not in the manual?

GE T60 Specifications

General IconGeneral
Frequency50/60 Hz
MountingPanel Mount
Protection FunctionsOvercurrent
Communication ProtocolsDNP3
Operating Temperature+70°C
EnclosureIP54 (front panel)