B-46 T60 Transformer Protection System GE Multilin
B.4 MEMORY MAPPING APPENDIX B
B
7149 Ground Distance Zone 1 Reverse Reach 0.02 to 500 ohms 0.01 F001 200
717A Ground Distance Zone 1 Reverse Reach RCA 30 to 90 degrees 1 F001 85
714B Reserved (7 items) 0 to 65535 --- 1 F001 0
7152 ...Repeated for Ground Distance Zone 2
7174 ...Repeated for Ground Distance Zone 3
7196 ...Repeated for Ground Distance Zone 4
71B8 ...Repeated for Ground Distance Zone 5
Phase Directional Overcurrent (Read/Write Grouped Setting) (2 Modules)
7200 Phase Directional Overcurrent 1 Function 0 to 1 --- 1 F102 0 (Disabled)
7201 Phase Directional Overcurrent 1 Source 0 to 5 --- 1 F167 0 (SRC 1)
7202 Phase Directional Overcurrent 1 Block 0 to 4294967295 --- 1 F300 0
7204 Phase Directional Overcurrent 1 ECA 0 to 359 --- 1 F001 30
7205 Phase Directional Overcurrent 1 Pol V Threshold 0 to 3 pu 0.001 F001 700
7206 Phase Directional Overcurrent 1 Block Overcurrent 0 to 1 --- 1 F126 0 (No)
7207 Phase Directional Overcurrent 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
7208 Phase Directional Overcurrent 1 Events 0 to 1 --- 1 F102 0 (Disabled)
7209 Reserved (8 items) 0 to 1 --- 1 F001 0
7211 ...Repeated for Phase Directional Overcurrent 2
Neutral Directional Overcurrent (Read/Write Grouped Setting) (2 Modules)
7230 Neutral Directional Overcurrent 1 Function 0 to 1 --- 1 F102 0 (Disabled)
7231 Neutral Directional Overcurrent 1 Source 0 to 5 --- 1 F167 0 (SRC 1)
7232 Neutral Directional Overcurrent 1 Polarizing 0 to 4 --- 1 F230 0 (Voltage)
7233 Neutral Directional Overcurrent 1 Forward ECA -90 to 90 ° Lag 1 F002 75
7234 Neutral Directional Overcurrent 1 Forward Limit Angle 40 to 90 degrees 1 F001 90
7235 Neutral Directional Overcurrent 1 Forward Pickup 0.006 to 30 pu 0.001 F001 50
7236 Neutral Directional Overcurrent 1 Reverse Limit Angle 40 to 90 degrees 1 F001 90
7237 Neutral Directional Overcurrent 1 Reverse Pickup 0.002 to 30 pu 0.001 F001 50
7238 Neutral Directional Overcurrent 1 Target 0 to 2 --- 1 F109 0 (Self-reset)
7239 Neutral Directional Overcurrent 1 Block 0 to 65535 --- 1 F300 0
723B Neutral Directional Overcurrent 1 Events 0 to 1 --- 1 F102 0 (Disabled)
723C Neutral Directional Overcurrent 1 Polarizing Voltage 0 to 1 --- 1 F231 0 (Calculated V0)
723D Neutral Directional Overcurrent 1 Op Current 0 to 1 --- 1 F196 0 (Calculated 3I0)
723E Neutral Directional Overcurrent 1 Offset 0 to 250 ohms 0.01 F001 0
723F Neutral Directional Overcurrent 1 Pos Seq Restraint 0 to 0.5 --- 0.001 F001 63
7240 Reserved 0 to 1 --- 1 F001 0
7241 ...Repeated for Neutral Directional Overcurrent 2
Breaker Arcing Current Settings (Read/Write Setting) (6 Modules)
7290 Breaker 1 Arcing Amp Function 0 to 1 --- 1 F102 0 (Disabled)
7291 Breaker 1 Arcing Amp Source 0 to 5 --- 1 F167 0 (SRC 1)
7292 Breaker 1 Arcing Amp Init 0 to 4294967295 --- 1 F300 0
7294 Breaker 1 Arcing Amp Init B 0 to 4294967295 --- 1 F300 0
7296 Breaker 1 Arcing Amp Init C 0 to 4294967295 --- 1 F300 0
7298 Breaker 1 Arcing Amp Delay 0 to 65.535 s 0.001 F001 0
7299 Breaker 1 Arcing Amp Limit 0 to 50000 kA2-cyc 1 F001 1000
729A Breaker 1 Arcing Amp Block 0 to 4294967295 --- 1 F300 0
729C Breaker 1 Arcing Amp Target 0 to 2 --- 1 F109 0 (Self-reset)
729D Breaker 1 Arcing Amp Events 0 to 1 --- 1 F102 0 (Disabled)
729E ...Repeated for Breaker 2 Arcing Amp
72AC ...Repeated for Breaker 3 Arcing Amp
72BA ...Repeated for Breaker 4 Arcing Amp
72C8 ...Repeated for Breaker 5 Arcing Amp
72D6 ...Repeated for Breaker 6 Arcing Amp
Disconnect (Breaker) Switch (Read/Write setting) (24 Modules)
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 74)
ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT