– 41 –
TEST BLEACH VALVE - Energizes bleach
valve.
TEST SPECIAL ADDITIVE - Energizes special
additive valve.
WATER LEVEL FREQUENCY - Factory test
only, no value as a service test.
DRY LOAD SENSING DATA - Factory test
only, no value as a service test.
TEST PUMP MOTOR - Energizes the drain
pump. (Washer lid should be closed.)
COM TEST - Part of a serial communication
test between the washer and dryer. This test
runs a self diagnostic of the internal
communications within the main board.
Should the test fail, the LCD screen displays
COM ERROR when the TEST SOFTENER
VALVE test is activated. This is displayed
above the CONTRAST 90/180 box. Replace
the main board if COM ERROR is displayed.
b. To stop the current test and move to the
next test, press the START/STOP pad.
c. Each test starts as soon as it is displayed
on the screen and each test will time out
after 5 minutes if the START/STOP pad is
not pressed again.
d. To exit the TEST LOAD screen, press
START/STOP to scroll down the test list
until the screen darkens. Press any pad
on the keypanel membrane and the HOME
screen is displayed.
e. Once a test has been started, previous
tests cannot be accessed again. To
access the TEST LOAD screen again,
repeat steps 1 through 6.
Factory Test Information
Note: The lid can be open during all tests except
for the pump motor test.
The IPM TEMP, ATM TEMP, and WATER TEMP
tests are activated as soon at the TEST LOAD
screen is displayed. All other tests will time out
after 5 minutes.
TEST BRAKE RESISTOR - The control
measures a voltage drop across the resistor.
An error is displayed if the resistor fails the
test.
IPM TEMP - Displays the inverter board temp
in °C.
ATM TEMP - Displays the air temperature
within the inverter housing in °C.
Note: This temperature affects the LCD
display. If the temperature is below 30°F
(-1°C) the LCD backlight will not come on.
WATER TEMP - Displays the water
temperature in °C at the tub thermistor.
CONTRAST 90/180 - Displays current
screen resolution of 90 or 180. This can be
changed by pressing the CONTRAST box on
the LCD screen.
180 - High Contrast (dark)
90 - Low Contrast (light)
TEST COLD VALVE - Energizes the cold
water valve.
TEST HOT VALVE - Energizes the hot water
valve.