EN
Problem: Repeat switch-o accuracy not within the tolerance of the
test certicate.
Remedy: Bring device to constant operating temperature, e.g. by
idling for approx. 5 min.
11 Technical Data
Permissible ambient temperature: -10 °C to +40 °C (14 °F to 104 °F)
Device:
Protection class according to DIN 40050: IP 32
Emission: Continuous sound pressure level
according to DIN 45635 is on average 78.7 dB (A)
Vibration is less than 2,5 m/s²
Battery:
Battery type: Li-Ion battery
Voltage: 18V
Nominal capacity: 5 Ah
No memory eect.
Charging time: max. 70 min.
Number of cells: 10
Charger:
Prim.: 220–240V; 50/60 Hz Prim.: 110–120V; 50/60 Hz
Second: 18VDC 4,1A
Power: 110W
Connector with IEC C14
Protection class: IP 32
Protective insulation: Protection class II