156 ADV200 • Functions description and parameters list
These parameters are available in the src analog parameter selection lists.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.21 5850FLRev1mon INT32 32BIT 0 0 0 ER FVS
23.8.22 5852FLRev2mon INT32 32BIT 0 0 0 ER FVS
23.8.23 5854FLRev3mon INT32 32BIT 0 0 0 ER FVS
23.8.24 5856FLRev4mon INT32 32BIT 0 0 0 ER FVS
Display of data selected via parameters FLRevXSlavesel corresponding (PAR 5822 ... 5828).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.25 5822FLRev1slavesel UINT16 0 0 31 ERWZ FVS
23.8.26 5824FLRev2slavesel UINT16 0 0 31 ERWZ FVS
23.8.27 5826FLRev3slavesel UINT16 0 0 31 ERWZ FVS
23.8.28 5828FLRev4slavesel UINT16 0 0 31 ERWZ FVS
Parameter signicant only for Master drive, indicates what data of which Slave drive to display in parameter
MonrevXFL (you can choose to display word 1 or 2 of a Slave with address from 2 to 16). The code used
assigns the signicance of the rst word of the Slave at address 2 to value 0, value 1 for the rst word of the
Slave at address 3 …. 14 rst word of the Slave at address 16, 15 has no signicance, 16 second word of
Slave at address 2 … 30 second word of Slave at address 16.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.29 5720Syncslavemon BIT 16 0 0 1 ER FVS
This parameter is not signicant on the master drive.
On the slave drives this parameter indicates the state of the function that enables Pwm signals to be synchro-
nised with the Pwm signals of the master and execution of control tasks to be synchronised with execution of
control tasks of the master.
0 Slave not synchronised
1 Slave synchronised
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.30 5722FLfaultcode UINT32 0 0 0 ER FVS
This parameter is used to display the cause of the FastLink fault alarm.
See chapter C - FastLink Fault.