156 ADV200 Functions description and parameters list
These parameters are available in the src analog parameter selection lists.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.21 5850FLRev1mon INT32 32BIT 0 0 0 ER FVS
23.8.22 5852FLRev2mon INT32 32BIT 0 0 0 ER FVS
23.8.23 5854FLRev3mon INT32 32BIT 0 0 0 ER FVS
23.8.24 5856FLRev4mon INT32 32BIT 0 0 0 ER FVS
Display of data selected via parameters FLRevXSlavesel corresponding (PAR 5822 ... 5828).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.25 5822FLRev1slavesel UINT16 0 0 31 ERWZ FVS
23.8.26 5824FLRev2slavesel UINT16 0 0 31 ERWZ FVS
23.8.27 5826FLRev3slavesel UINT16 0 0 31 ERWZ FVS
23.8.28 5828FLRev4slavesel UINT16 0 0 31 ERWZ FVS
Parameter signicant only for Master drive, indicates what data of which Slave drive to display in parameter
MonrevXFL (you can choose to display word 1 or 2 of a Slave with address from 2 to 16). The code used
assigns the signicance of the rst word of the Slave at address 2 to value 0, value 1 for the rst word of the
Slave at address 3 …. 14 rst word of the Slave at address 16, 15 has no signicance, 16 second word of
Slave at address 2 … 30 second word of Slave at address 16.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.29 5720Syncslavemon BIT 16 0 0 1 ER FVS
This parameter is not signicant on the master drive.
On the slave drives this parameter indicates the state of the function that enables Pwm signals to be synchro-
nised with the Pwm signals of the master and execution of control tasks to be synchronised with execution of
control tasks of the master.
0 Slave not synchronised
1 Slave synchronised
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
23.8.30 5722FLfaultcode UINT32 0 0 0 ER FVS
This parameter is used to display the cause of the FastLink fault alarm.
See chapter C - FastLink Fault.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals