46 ADV200 Functions description and parameters list
Currentthrmon is enabled. The signal is disabled when the motor speed falls below the threshold - the toler-
ance band. If the threshold value is lower than the value set in 982Currentthrhyster, the result produced is
always 0. The value set in this parameter is active in both directions of rotation.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
10.15 982 Currentthrhyster perc UINT16 0 0 100 RW FVS
Setting of the tolerance band around the current threshold. A value of 100% corresponds to the value of the
drive heavy duty continuous current, displayed in parameter 488Drivecontcurrent, when parameter 566
Driveoverloadmode is set to Heavyduty, and no derating of the drive continuous current has been activated
due to any modication of Mains voltage, Switching frequency and Ambient temperature.
The drive heavy duty continuous current value to be used is the factory setting read in PAR 488 Drivecont
current.
The tolerance band is the same for both directions of rotation of the motor.

Table of Contents

Other manuals for gefran ADV200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran ADV200 and is the answer not in the manual?

gefran ADV200 Specifications

General IconGeneral
Brandgefran
ModelADV200
CategoryInverter
LanguageEnglish

Related product manuals