917334/BP0310 25
10. Keyswitch In a clockwise rotation, these positions are:
OFF Position – With the key vertical, power from the battery is disconnected
to the controls and instrument panel electrical circuits. This is the only posi-
tion the key can be inserted or removed from the keyswitch.
ON (or Run) Position With the key turned one position clockwise from
vertical, power from the battery is supplied to all control and instrument panel
electrical circuits.
START Position – With the key turned fully clockwise, the electric starter
energizes, start the engine. Release the key to the RUN position after the
engine starts.
Note: The engine cannot be started unless the operator is sitting in the seat and
the restraint bar is lowered.
11. Parking Brake Switch – Used to manually apply the parking brake. The red
indicator on the switch lights when the parking brake is applied.
12. Light Switch – Controls all the lights on the loader. Symbols denote the four
positions of the light switch. In a clockwise direction these are:
•OFF
•Tail Lights ON
Front Work Lights with Tail Lights ON
both Front and Rear Work Lights
For the lights to function, the keyswitch must be in the RUN position.
13. Circuit Breakers Four circuit breakers on the instrument panel protect the
loaders electrical circuits.
Important: Do not attempt to defeat the circuit protection by jumping across a
circuit breaker or by using a higher amperage circuit breaker.
14. Accessory Outlet – 12-volt DC power outlet.