917334/BP0310 47
Reinstallation
1. Check the inside of the housing for any damage that may interfere with the
elements.
2. Be sure that the element sealing surfaces are clean.
3. Insert the element(s), making sure that they are seated properly.
4. Secure the cover to the housing with clamps.
5. Check the hose connections and be sure they are all clamped and tightened
properly.
6. Reset the restriction indicator by pressing the reset button.
Engine Service
Check Engine Mounting Hardware
All bolts that secure the engine mounting brackets to the engine and the loader
frame should be checked and re-tightened as necessary.
Allow hot engine and hydraulic system compo-
nents to cool before servicing.
Checking Engine Oil Level
Important: For new units, the initial oil
change should be after the first 50 hours.
Open the rear door and engine access
cover. Pull out the dipstick and check the
oil level. Markings on the dipstick repre-
sent FULL and LOW (add oil) levels.
Refer to the Maintenance Interval Chart
(page 67) for the service interval for
replacing the engine oil and filter.
WARNING
Figure 28 Oil Dipstick
and Fill Cap
1. Oil Dipstick
2. Oil Fill Cap
1
2