Local System or C.S. Reporting System
(Appears for New Panel Only)
Press YES (
E) button for all zones to report; press NO (F) button
for no zones to report (LOCAL SYSTEM).
Exit/Entry Zones (Appears for New Panel Only)
Directly enter the zone numbers which are to be used as Exit/Entry zones.
Valid entries are from 01 to 96. Directly enter each zone number, including
leading zeros. Use number buttons
1 through 9.
NOTE:
Press
the
0 button for a zero. Press
J
to save and then repeat for any
additional zone(s). Press NEXT (
E
) button to proceed.
NOTE: Exit/Entry Zones will have an entry delay of 30 seconds and an exit
delay of 60 seconds. Chime will automatically be programmed for all E/E
zones. If you are programming a 2 Area system, enter all of the zones
required for Areas 1 & 2.
Interior Zones
(Appears for New Panel Only)
Directly enter the zone numbers which are to be used as Interior Zones.
Valid entries are from 01 to 96. Directly enter each zone number, including
leading zeros. Use number buttons
1 through 9.
NOTE:
Press
the
0 button for a zero. Press
J
to save and then repeat for any
additional zone(s). Press NEXT (
E) button to proceed.
NOTE: All Interior zones will also be automatically programmed as “Exit/
Entry Follower” zones. If you are programming a 2 Area system, enter all
the zones required for Areas 1 & 2.
Number of Keypads in Area 1
Directly enter the total number of Keypads to be installed in Area 1. Valid
entries are from 01 to 15. Directly enter the number of keypads, including
leading zeros. Use number buttons
1
through
9
. NOTE: Press
the
0 button for a zero. Press
J
to save . Press NEXT (E) button
to proceed.
Number of Keypads in Area 2
Directly enter the total number of Keypads to be installed in Area 2. Valid
entries are from 01 to 15. Directly enter the number of keypads, including
leading zeros. Use number buttons
1
through
9
. NOTE: Press
the
0 button for a zero. Press
J
to save . Press NEXT (E) button
to proceed.
(Press YES or NO)
REPORT
ALL ZN?
Y/N
(Direct Entry)
ENT EE
ZN# 00
(Direct Entry)
ENTFOL
ZN# 00
(Direct Entry)
ENT A1
#KP 01
(Direct Entry)
ENT A2
#KP 00
GEM-RP2ASe2 Keypad: CS Reporting, Exit/Entry Zones, Interior Zones & Keypads per Area

Table of Contents

Other manuals for Gemini GEM-P9600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemini GEM-P9600 and is the answer not in the manual?

Gemini GEM-P9600 Specifications

General IconGeneral
BrandGemini
ModelGEM-P9600
CategorySecurity System
LanguageEnglish

Related product manuals