4.2 Batteries
4.2.1 Operating Principles
The battery must be charged prior to using it for the first time because it is delivered with
an energy content as low as possible.
The permissible temperature range for charging is between 10 °C to +55 °C / +14 °F
to + 131 °F. For optimal charging we recommend charging the batteries at a low ambient
temperature of +10 °C to +45 °C/ +50 °F to 113 °F if possible.
It is normal for the battery to become warm during charging. Using the chargers recom-
mended by GeoMax, it is not possible to charge the battery if the temperature is too high.
For new batteries or batteries that have been stored for a long time (> three months), it is
effectual to make only one charge/discharge cycle.
For Li-Ion batteries, a single discharging and charging cycle is sufficient. We recommend
carrying out the process when the battery capacity indicated on the charger or on a
GeoMax product deviates significantly form the actual battery capacity available.
The batteries can be operated from 30 °C to +65 °C/22 °F to +149 °F.
Low operating temperatures reduce the capacity that can be drawn.
High operating temperatures reduce the service life of the battery.
4.2.2 Insert and Remove the Battery
1b
1b
1b
1a
1a
1a
3
3
2
2
6
6
7
7
8
8
24056_001
The batteries are inserted at the bottom of the Zenith60.
1. To remove a battery:
a) Push the slide fastener of the battery compartment in the direction of the
open-lock symbol.
b) Press the button to open the battery compartment.
2. Push the battery sideward to release the battery from its fixed position.
3. Remove the battery.
4. To insert the battery, push the slide fastener of the battery compartment in the
direction of the open-lock symbol.
5. Open the battery compartment.
6. Insert the battery into the battery compartment aligning the contacts.
7. Slide the battery in the compartment so that it locks into position.
8. Close the battery compartment and push the slide fastener in the direction of the
closed-lock symbol.
Charging / first-time use
Operation/Discharging
Change battery
step-by-step
23
Operation

Other manuals for GeoMax Zenith60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GeoMax Zenith60 Series and is the answer not in the manual?

GeoMax Zenith60 Series Specifications

General IconGeneral
BrandGeoMax
ModelZenith60 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals