38
3.5 Keypad
When accessing an entry using GV-RKD1352, you can enter the door’s PIN code on the
keypad or present the card and then enter the card’s PIN code on the keypad to be granted
access. The access mode is defined on GV-ASManager.
1. 0~9 Number Keys: Press the number keys to enter the PIN code.
2. # Key: Press the # key to confirm the PIN code.
3. ﹡Key: Press the ﹡key to cancel the PIN code.
IMPORTANT: For Card and PIN Code mode, users need to enter the card’s PIN code,
plus # to confirm the code, and then present the card for access granted.
3.6 LED Status and Beeper
By default, the reader has the following LED status and beeper actions:
Condition Wiegand RS-485
Standby Constant Red No light
Access Denied Beep once (No LED) Flash Red momentarily +
Beep three times
Access Granted Beep once (No LED) Flash Green momentarily +
Beep twice
For Wiegand connection, the reader comes with external control wires for Green LED and
Beeper. You can connect these control wires to GV-AS Controller to change the default
settings of the LED and Beeper.
3.7 Specifications
For details, please see the datasheet.
For the number of readers supported by a variety of GeoVision controllers, see the
compatibility table
.