Page 13
English
(2a) E-Stop Recovery Procedure
To recover from an E-Stop:
1) If an E-Stop switch is pressed, twist and release. Go to step 3.
2) If an E-Stop bumper arm was pushed, go to step 3.
3) Push the Primary Reset button on the control box (see Figure 6).
4) Push the Reset button on the control box status board (see Figure 6).
To recover a cut file that was functioning before the E-Stop:
1) On the Toolpath menu, select Clear Halt Marker.
2) On the Machine menu, select Restart Aborted Job.
3) Press the Enter key on the table control panel keypad.
(3) Beam Control Panel (BCP)
The beam control panel (BCP) is located on the keypad side of the Beam.
The keypad, joystick, E-Stop switch and E-Stop bumper arms are on the
beam control panel.