Page 16
Enter key – Starts a cut job or continues cutting after a
pause and used to execute hardware commands.
Minus key – Used in specified calibrations.
Down Arrow key – Used to navigate menus and in
specified calibrations.
Note: The machine can be paused during cutting by pushing
any keypad key or the space bar on the computer.
(3b) Entering and Exiting Local and Online Modes
From any mode, press the Cancel key on the keypad once or twice to
return to online mode.
From online mode to local mode:
1) Press the Up Arrow key or Down Arrow key on the beam control
panel keypad.
2) Local mode appears on the display screen on the beam control panel
keypad.
To online mode from local mode: Press the Cancel key on the beam
control panel keypad until online mode appears on the display screen.
To Jog:
1) Go to local mode.
2) Press the Enter key. Jogging appears on the beam control panel
keypad display screen.
3) To move the beam and head, move the joystick.
To exit any mode, press the Cancel key until the desired mode appears on
the display screen on the beam control panel keypad.